Surfacing
DRYTEKT 920
DRYTEKT 920 is a high quality self-leveling, cement-based product specially formulated for use as an interior wear surface. Available in either grey or white formulation.
![]() |
![]() |
![]() |
![]() |
|
Concrete
|
Wood
|
Ceramic
Tile
|
Vinyl
|
![]() |
![]() |
![]() |
![]() |
|
Radiant
Heating
|
For
use as underlayment
|
Wear
surface
|
Fast
drying
|
![]() |
![]() |
![]() |
![]() |
|
Pumpable
Pourable
|
Hand
applied
|
Indoor
|
Outdoor
|
PERFORMANCE CHARACTERISTICS
TECHNICAL INFORMATION
PREPARATION
OF SUBSTRATE
Substrate shall be free from dust, oil or any contaminants which may contribute
to decreased bond. Weak surfaces must be mechanically cleaned to sound and solid
substrates by shot-blasting, scarifying or similar. Remove any loose particles
such as adhesive residues and then vacuum. Surface tensile bond strength of
substrate should be minimum 217 PSI (1.5 MPa). Surface should be primed with
DRYTEKT Primer. Substrate temperature should be a minimum 43°F (+6°C) during
application and air temperature maintained between 50-77°F (10-25°C). Adequate
ventilation should be provided to ensure uniform drying. Moisture level of substrate
should be RH 95% or less prior to application of DRYTEKT 920. Contraction joints,
construction joints and cracks in the substrate which may be subject to movement
after installation of DRYTEKT 920 must be maintained as joints in the new surface.
MIXING
DRYTEKT 920 should be mixed with 4.5 to 5 quarts (4-4.5 L) of water per 55 lb.bag.
Do not over-water. For manual application, add product to water and mix for
2-3 minutes with a heavy duty drill (650 rpm) to obtain a lump-free mix. DRYTEKT
920 can also be used in most pump equipment, please consult with Drytek representative
to verify equipment compatibility. A slump test should always be performed to
ensure that mix is homogenized and free from separation.
APPLICATION
Pour blended material onto substrate at a thickness of 1/8"-2" (3-50 mm) for
all surfaces. Perform slump test and adjust water accordingly until ideal patty
size of 10-11 inches is obtained. DRYTEKT 920 has a liquid merger time of 3-5
minutes at 68°F (20°C). Immediately smooth the poured slurry with a notched
trowel or smoother. After intitial set of material (approx. 20-30 min.) remove
all overlap marks, seams and inconsistencies by scraping with steel trowel.
Light ventilation during and after application is recommended but dehumidifiers
should not be used for the first two days. Curing membranes are not required.
SURFACE FINISHES
DRYTEKT 920 does not require sealers or coatings for use as wear surface. However,
DRYTEKT 920 accepts direct application of most commercial toppings, including
acrylic, polyurethane and epoxy-based systems. Consult toppings manufacturer
for specific procedures. Please contact your DRYTEKT representative for specific
advice.
TRAFFICABILITY
Allow 1-2 hours for foot traffic, 24 hours for light traffic and can bear full
load (ie. fork truck etc) after 7 days.
LIMITATIONS
Not for installation over wood or vinyl substrates. Apply only over ceramic
or quarry tile which is applied to a concrete substrate. For indoor applications
only. Not for applications exposed to continious water of intrusion. Must allow
for eventual drying of substrate.
PACKAGING &
STORAGE
DRYTEKT 920 is available in 55 lb. vinyl-lined paper bags. Product should be
stored in dry conditions and in original packaging. Use within 6 months of date
of manufacture.
Information contained within this brochure is not legally binding. Information contained herein is in good faith but Drytek Flooring Solutions Inc (DRYTEK) will not be held liable for information which has been misunderstood or used incorrectly. DRYTEK will not be held liable for improperly applied or used products, nor the specific use or pertinency of a product to a particular project. Information contained herein or otherwise administered by DRYTEK or its affiliates is based on the current and present knowledge of the products when used under normal circumstances and according to DRYTEK recommendations.
WARNING: Dust may cause skin, eye, nose, throat, or respiratory irritation. Avoid dust inhalation and exposure to dust. If dusty, wear a NIOSH/MSHA-approved dust respirator. Use proper ventilation to reduce dust exposure. Portland cement is strongly alkaline and can be corrosive to eyes, skin and respiratory tract. Wear eye and skin protection. If eye contact occurs, immediately flush thoroughly with water for 15 minutes and get medical attention. Do not ingest. If ingested and any discomfort occurs, call physician.